BP124432 - 6971 Island Highway North-Bldg A - new address-

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP124432 - 6971 Island Highway North-Bldg A - new address-
Neighbourhood: Dover    
Street Address: 6971 Island Highway North-Bldg A - new address-
Type of Application: Commercial / Multi / Industrial
File Number: BP124432
Date Application Submitted: May 11, 2018
Application Description: Residential Apartment, 51 units - Bldg A - New address 6971 Island Highway-
North Grove: 51 Residential units - 4 storeys , Group C, 3.2.2.50, 4 storey, fire alarm, sprinklered throughout, standpipes in exits. Building area for code purposes for building is 947.24 m2. Total gross floor areas (including stairwells and elevators) 1st storey = 947.24 m2 ; 2nd storey 940.13 m2; 3rd storey 942 m2 ; 4th storey 942 m2. Key FRR /FS are 1 Hour FRR/FS 50 STM between residential suites, 1 Hour FRR/FS for public corridor, floor assemblies and loadbearing supports. Storage rooms, exit stairs, elevators and machine room; all doors in fire separations to be self-closing with positive latching mechanisms. Rated roof provided for termination vertical 1 hour FRR/FS.. Vertical service spaces 45 min FS/FRR. No opening permitted between 1st and 2nd storey in entrance.

REVISION: Aug.09,2019-Changes to footing layout.
Application Status: COMPLETED
Permit Value: $7,500,000.00
Builder: WINDLEY CONTRACTING LTD
Issued Date: November 27, 2018
File Close Date: February 03, 2020
Expiry Date: November 27, 2020

Process Steps

Task Status
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

FAILED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

CANCELLED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
OCCUPANCY-OLD PASSED

2020-02-03

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.