BP120995 - Unit 101 - 679 Terminal

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP120995 - Unit 101 - 679 Terminal
Neighbourhood: Newcastle/Brechin    
Street Address: Unit 101 - 679 Terminal
Type of Application: Leasehold Improvements
File Number: BP120995
Date Application Submitted: June 24, 2015
Application Description: Unit #101 - Group D, 127.88 m2 (single exit). Tenant Improvement to create new hair salon.REVISION: AUG 11

Part 9, Two storey, Mixed-use building, sprinklered with fire alarm, first storey 450 m2 (existing 290.97m2), second storey 311m 2. First storey divided into 3 "Shell"" Group D" suites, with a 1 hr fire resistance rating/fire separation (FRR/FS) provided between the 1st storey units and one hour FRR/FS/50 STM provided between the first and second storey. Shell "Group D" 1st storey: #101=127.88 m2 (single exit); #102= 194.26 m2 (2 exits); #103 = 117.17 m2 (single exit); 2nd storey divided into 3 residential dwelling units with a one hour FRR/FS/50 STM between units and between 1st and 2 nd storey. Exiting from Residential units via rear exit stairs, openings in 1st storey protected with wired glass in steel frames.Residental #201 = 92.86 m2, #202 = 145.8 m2, #203 = 92.86 m2. (NOTE:Units #201 & #203 increased in sized by 9.985m2 each(total 19.97m2) for new permit.
Application Status: COMPLETED
Permit Value: $130,000.00
Builder: MCMANN HOMES
Issued Date: August 07, 2015
File Close Date: October 08, 2015
Expiry Date: August 07, 2017

Associated Properties

Address Zone More
679 TERMINAL AVENUE N COR2 Property Report
101   679 TERMINAL AVENUE N COR2 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

PASSED
UNDERSLAB INSULATION

Inspection required prior to placing slab concrete.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

FAILED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

FAILED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

FAILED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
FINAL-OLD

Final Approval as per requirements on plans.

CANCELLED
FINAL-OLD

Final Approval as per requirements on plans.

FAILED
FINAL-OLD

Final Approval as per requirements on plans.

PASSED

2015-10-08

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy