BP118917 - 104 - 6543 Portsmouth
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP118917 - 104 - 6543 Portsmouth | |
---|---|
Neighbourhood: | Dover |
Street Address: | 104 - 6543 Portsmouth |
Type of Application: | Leasehold Improvements |
File Number: | BP118917 |
Date Application Submitted: | August 30, 2013 |
Application Description: |
Dr. Michael Stochmal - office 79m2 D occupancy accessible, relocate one w/c add one w/c c/w shower, laundry room and 5 sink rough ins. 2 storey, Part 9 Building. Sprinklered. Building Area 501.35m2 Lower floor Area 501.35m2 - 'Group D' Occupancy: Upper floor 372m2 -'Group D' occupancy 45min FS/FRR required for floors, 1hr provided. 45min FRR columns or non combustible required, non combustible provided.(colums are appropriate for support of 45min rated floor BCBC 3.2.2.56) 45min supporting walls required, 1hr provided. 45min FS/FRR required for service shafts 1hr provided. 45min FS/FRR required for roof supporting an occupancy, 1hr provided. EBF of exit stair on east elevation non combustible cladding non combustible construction 1hr FRR |
Application Status: | COMPLETED |
Permit Value: | $90,000.00 |
Builder: | WESTMARK CONSTRUCTION LTD |
Issued Date: | October 04, 2013 |
File Close Date: | February 26, 2014 |
Expiry Date: | October 05, 2015 |
Associated Properties
Address | Zone | More |
---|---|---|
104 6543 PORTSMOUTH ROAD | CD6 | Property Report |
102 6543 PORTSMOUTH ROAD | CD6 | Property Report |
Process Steps
Task | Status |
---|---|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
FAILED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
CANCELLED |
OCCUPANCY-OLD |
PASSED
2014-02-26 |
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final Approval as per requirements on plans. |
CANCELLED |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.