BP113657 - 2217 Northfield Road

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP113657 - 2217 Northfield Road
Neighbourhood: Northfield    
Street Address: 2217 Northfield Road
Type of Application: Commercial / Multi-Res Alteration
File Number: BP113657
Date Application Submitted: January 26, 2009
Application Description: Change of occupancy to "D" office/service from a "C" single family dwelling. Part 9 Building, combustible, unsprinklered without fire alarm.

Convert 35 sq ft covered porch to interior building area by adding foundation and structure. Relocate and convert existing washroom to accessible washroom with 2 bathroom fixtures. Upgrade floor structure to allow 100 lbs / sq ft load including adding some strip footings and bearing into the crawl space. Relocate and convert doors to swing outwards, relocate partition walls, install beam, install emergency lighting and add interior finishes. Civil Engineering is included for the storm water management.

2009-05-20 Revision - New 5' x 8' roof added over a new 4' x 6' landing at the rear door bearing on two new footings.
Application Status: COMPLETED
Permit Value: $19,000.00
Building Area: 3.25 M2
34.98 ft2
Issued Date: April 22, 2009
File Close Date: September 22, 2009

Associated Properties

Address Zone More
2217 NORTHFIELD ROAD CS1 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
FOOTING/FORMS

Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

PASSED

2009-09-22

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy