BP131873 - 101-5200 Dublin Way, (Origin Optometry)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP131873 - 101-5200 Dublin Way, (Origin Optometry) | |
|---|---|
| Neighbourhood: | Pleasant Valley |
| Street Address: | 101-5200 Dublin Way, (Origin Optometry) |
| Type of Application: | Commercial / Multi-Res Alteration |
| File Number: | BP131873 |
| Date Application Submitted: | June 03, 2026 |
| Application Description: |
Tenant Improvement and Change of Use from Group E to Group D to combine CRU 101 with CRU 100 (Origin Optometry). Tenant now occupying the 431.3m2 GFA of the building. Scope of work includes: Removal of portion of existing party wall, new interior partitions, finishes, millwork, new/relocation of sprinkler heads to suit new layout, 5 new hand sinks and 1 new HWT, removal of 1 universal washroom, occupant load restricted to 50 persons due to washroom count. 1 HR FS/FRR to be maintained at service room, 45 min FS/FRR to be maintained at mezzanine stair corridor. Existing Building: (BP125509) BLDG A BCBC 2018 3.2.2.63 / .69 / Group D/E, 372.3 m2 building area, 431.3m2 GFA, 1-storey plus mezzanine, combustible construction / 45-min FS/FRR floor assemblies / 45-min. FS/FRR load-bearing supports. |
| Application Status: | ACTIVE |
| Permit Value: | $500,000.00 |
| Builder: | MEDICO CONSTRUCTION AND DESIGN LTD. |
| Issued Date: | August 17, 2026 |
| Expiry Date: | August 17, 2028 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 101 5200 DUBLIN WAY | CD5 | Property Report |
| 100 5200 DUBLIN WAY | CD5 | Property Report |
| 5200 DUBLIN WAY | CD5 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
FAILED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
FAILED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)