BP131293 - 2900 Cosgrove Crescent
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP131293 - 2900 Cosgrove Crescent | |
|---|---|
| Neighbourhood: | Departure Bay |
| Street Address: | 2900 Cosgrove Crescent |
| Type of Application: | Single / Two Family Alteration |
| File Number: | BP131293 |
| Date Application Submitted: | October 15, 2025 |
| Application Description: |
Alteration to existing home, addition to main floor, and adding secondary suite slab on grade Removal of existing Cosgrove driveway access, install new driveway access on Norfolk and install a new storm service REVISION 2026-MAR-05: New truss design, window and door sizes changed, added shower, small layout changes |
| Application Status: | ACTIVE |
| Permit Value: | $338,168.92 |
| Building Area: |
63.53 M2 683.83 ft2 |
| Builder: | WHEATCROFT CONSTRUCTION LTD |
| Issued Date: | February 02, 2026 |
| Expiry Date: | February 02, 2028 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 2900 COSGROVE CRESCENT | R5 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
FOOTING/FORMS
Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
|
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
|
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible |
PARTIAL |
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible |
PARTIAL |
|
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
FAILED |
|
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
PASSED |
|
UNDERSLAB RADON
Inspection of granular layer and piping |
FAILED |
|
UNDERSLAB RADON
Inspection of granular layer and piping |
PASSED |
|
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PARTIAL |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)