BP131264 - 6201 Dunbar Road, (#142 Pleasant Valley School)

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP131264 - 6201 Dunbar Road, (#142 Pleasant Valley School)
Neighbourhood: Chase River    
Street Address: 6201 Dunbar Road, (#142 Pleasant Valley School)
Type of Application: Commercial / Multi-Res Alteration
File Number: BP131264
Date Application Submitted: October 06, 2025
Application Description: Relocation and renovation of Portable learning studio #142. (89 m2)
Work includes: moving portable from 100 Ohio Street, new foundation, skirting, accessible ramp, exit stairs, new exterior building envelope, adding 1 hand wash sink, fire alarm tied to main school fire alarm panel.

Existing BCBC Group A2 3.2.2.28. Combustible construction. "Cluster of portables" considered one building via Alternative solution.

2026-JUL-16 REVISION: Revised mechanical room and equipment, add accessible ramp.
Application Status: COMPLETED
Building Area: 89.00 M2
957.99 ft2
Issued Date: March 02, 2026
File Close Date: September 21, 2026
Expiry Date: March 02, 2028

Associated Properties

Address Zone More
6201 DUNBAR ROAD CS1 Property Report
100 OHIO WAY CS1 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
MONITORING FIELD REVIEW

A building official may attend the site from time to time during the course of construction to ascertain that the field reviews are taking place and to monitor the field reviews undertaken by the registered professional.

MONITORED
PLUMBING FINAL

All fixtures must be in place.

PASSED
FINAL

Final approval as per requirements on plans.

CANCELLED
FINAL

Final approval as per requirements on plans.

CANCELLED
FINAL

Final approval as per requirements on plans.

PASSED

2026-09-21

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.