BP130853 - 1515/1517 Marban Road (Inspection Only) Parent163 Alberta Rd
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP130853 - 1515/1517 Marban Road (Inspection Only) Parent163 Alberta Rd | |
|---|---|
| Neighbourhood: | Chase River |
| Street Address: | 1515/1517 Marban Road (Inspection Only) Parent163 Alberta Rd |
| Type of Application: | Commercial / Multi / Industrial |
| File Number: | BP130853 |
| Date Application Submitted: | February 06, 2025 |
| Application Description: |
1515/1517 Marban Road: BCBC2024 Group C, Part 9 combustible construction. Sprinklered to NFPA 13 D by bylaw. 2 storey dwelling with attached garage, slab on grade construction, 1 HR FRR/FS between dwelling units. building area 162.79 m2, GFA 277.09 m2. |
| Application Status: | ACTIVE |
| Builder: | KSG CONSULTING LTD |
| Issued Date: | October 29, 2025 |
| Expiry Date: | October 29, 2027 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 163 ALBERTA ROAD | R5 | Property Report |
| 1515 MARBAN ROAD | Property Report | |
| 1517 MARBAN ROAD | Property Report |
Process Steps
| Task | Status |
|---|---|
|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
|
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
SCHEDULED |
|
STORM CONNECTION
Pipe and connection must be visible for inspection. |
PASSED |
|
SANITARY CONNECTION
Pipe and connection must be visible for inspection. |
PASSED |
|
WATER CONNECTION
Pipe and connection must be visible for inspection. |
PARTIAL |
|
UNDERSLAB RADON
Inspection of granular layer and piping |
PASSED |
|
LATERAL BRACING & SHEATHING
All nailing and blocking associated with braced wall panels to be completed for this inspection. Wood-based interior braced wall panels to be sheathed. Exterior braced wall panel locations to be clearly marked out on the interior and exterior. Interior braced wall panels to be clearly marked so their location can be seen now and later at the time of INTERIOR BRACED WALL PANEL INSPECTION. Additional anchor bolts shall be installed two per braced wall panel where a building contains framed walls supporting more than two floors. |
PASSED |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)