BP130434 - 24/26 Leam Road

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP130434 - 24/26 Leam Road
Neighbourhood: Diver Lake    
Street Address: 24/26 Leam Road
Type of Application: Commercial / Multi / Industrial
File Number: BP130434
Date Application Submitted: November 06, 2024
Application Description: 3-storey attached duplex development with secondary suites on one lot. Building classification part 9 group C residential, sprinklered (GFA: 421.45sqm). 1 hour fire-resistance rating required for party wall.

Dwelling A (26 Leam Road) GFA is 178.86 m². Dwelling B (24 Leam Road) GFA is 176.88 m².
Application Status: ACTIVE
Permit Value: $850,000.00
Builder: MOUNT BENSON DEVELOPMENTS INC
Issued Date: May 28, 2025
Expiry Date: May 28, 2027

Associated Properties

Address Zone More
24 LEAM ROAD R5 Property Report
24 LEAM ROAD Property Report
26 LEAM ROAD Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PARTIAL
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PASSED
UNDERSLAB INSULATION

Inspection required prior to placing slab concrete.

PASSED
STORM CONNECTION

Pipe and connection must be visible for inspection.

PASSED
SANITARY CONNECTION

Pipe and connection must be visible for inspection.

PASSED
WATER CONNECTION

Pipe and connection must be visible for inspection.

PASSED
UNDERSLAB RADON

Inspection of granular layer and piping

FAILED
UNDERSLAB RADON

Inspection of granular layer and piping

PASSED
LATERAL BRACING & SHEATHING

All nailing and blocking associated with braced wall panels to be completed for this inspection. Wood-based interior braced wall panels to be sheathed. Exterior braced wall panel locations to be clearly marked out on the interior and exterior. Interior braced wall panels to be clearly marked so their location can be seen now and later at the time of INTERIOR BRACED WALL PANEL INSPECTION. Additional anchor bolts shall be installed two per braced wall panel where a building contains framed walls supporting more than two floors.

FAILED
LATERAL BRACING & SHEATHING

All nailing and blocking associated with braced wall panels to be completed for this inspection. Wood-based interior braced wall panels to be sheathed. Exterior braced wall panel locations to be clearly marked out on the interior and exterior. Interior braced wall panels to be clearly marked so their location can be seen now and later at the time of INTERIOR BRACED WALL PANEL INSPECTION. Additional anchor bolts shall be installed two per braced wall panel where a building contains framed walls supporting more than two floors.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

CANCELLED
INTERIOR BRACED WALL PANELS

The location of interior braced wall panels to be clearly indicated. This inspection is to take place prior to the installation of tape and joint compound.

CANCELLED
APPROVAL-ENGINEERING

Approval required prior to Occupancy

REQUIRED
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.