BP130408 - 6123 Pine Ridge Crescent - House B (INSPECTION ONLY)

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP130408 - 6123 Pine Ridge Crescent - House B (INSPECTION ONLY)
Neighbourhood: Pleasant Valley    
Street Address: 6123 Pine Ridge Crescent - House B (INSPECTION ONLY)
Type of Application: Commercial / Multi / Industrial
File Number: BP130408
Date Application Submitted: October 27, 2024
Application Description: New construction of two single-family dwellings on slab on grade with secondary suites on one lot - House A & B
Sprinkler systems added - GFA: 481.42 sqm

House A (BP130407) GFA is 240.71 m². Second Dwelling (BP130408) GFA is 240.71 m². DCC's charged at single family unit rate on House B for a maximum of 170 m². 1 SFD credit applied to House A.

BP130406 Main Permit
BP130407 House A - Inspection Only (GFA is 240.71m²)
Application Status: ACTIVE
Permit Value: $300,000.00
Builder: MJP HOMES LTD
Issued Date: April 08, 2025
Expiry Date: April 08, 2027

Associated Properties

Address Zone More
6121 PINE RIDGE CRESCENT R5 Property Report
6123 PINE RIDGE CRESCENT Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PARTIAL
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PARTIAL
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PASSED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PASSED
UNDERSLAB INSULATION

Inspection required prior to placing slab concrete.

PASSED
STORM CONNECTION

Pipe and connection must be visible for inspection.

PARTIAL
STORM CONNECTION

Pipe and connection must be visible for inspection.

PASSED
SANITARY CONNECTION

Pipe and connection must be visible for inspection.

PASSED
WATER CONNECTION

Pipe and connection must be visible for inspection.

PARTIAL
WATER CONNECTION

Pipe and connection must be visible for inspection.

FAILED
WATER CONNECTION

Pipe and connection must be visible for inspection.

PASSED
UNDERSLAB RADON

Inspection of granular layer and piping

FAILED
UNDERSLAB RADON

Inspection of granular layer and piping

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
LATERAL BRACING & SHEATHING

All nailing and blocking associated with braced wall panels to be completed for this inspection. Wood-based interior braced wall panels to be sheathed. Exterior braced wall panel locations to be clearly marked out on the interior and exterior. Interior braced wall panels to be clearly marked so their location can be seen now and later at the time of INTERIOR BRACED WALL PANEL INSPECTION. Additional anchor bolts shall be installed two per braced wall panel where a building contains framed walls supporting more than two floors.

PASSED
INTERIOR BRACED WALL PANELS

The location of interior braced wall panels to be clearly indicated. This inspection is to take place prior to the installation of tape and joint compound.

PASSED
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.