BP130144 - 7-6404 Metral Drive
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP130144 - 7-6404 Metral Drive | |
|---|---|
| Neighbourhood: | Pleasant Valley |
| Street Address: | 7-6404 Metral Drive |
| Type of Application: | Commercial / Multi-Res Alteration |
| File Number: | BP130144 |
| Date Application Submitted: | June 07, 2024 |
| Application Description: |
Unit 7 (114.5 m2) change of use from Group D to Group E for grocery store. Demolish existing two-piece washroom and provide new BCBC 2024 universal washroom in existing room with sink. Demolish partitions and three existing sinks at front of Unit 7 for new grocery shelving/storefront. Existing 2-hr FRR/FS between Unit 6 (Group A2) to remain, and existing 45-min FRR/FS between Unit 8 (Group E) and Unit 9 (Group E) to remain. Existing Building Classification: BCBC 2006 3.2.2.61. (BCBC 2024 3.2.2.70.) Group E, 1271 m2 building area, one storey, facing 3 streets, unsprinklered, combustible building. Floor assembly and supports 3/4 hr FRR. |
| Application Status: | COMPLETED |
| Permit Value: | $30,000.00 |
| Issued Date: | November 14, 2024 |
| File Close Date: | January 22, 2025 |
| Expiry Date: | November 14, 2026 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 6404 METRAL DRIVE | CC4 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
|
PLUMBING FINAL
All fixtures must be in place. |
PASSED |
|
FINAL
Final approval as per requirements on plans. |
FAILED |
|
FINAL
Final approval as per requirements on plans. |
PASSED
2025-01-22 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)