BP130092 - 101-4474 Wellington Road (KMA)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP130092 - 101-4474 Wellington Road (KMA) | |
---|---|
Neighbourhood: | Diver Lake |
Street Address: | 101-4474 Wellington Road (KMA) |
Type of Application: | Leasehold Improvements |
File Number: | BP130092 |
Date Application Submitted: | May 31, 2024 |
Application Description: |
Unit # 101 - Complete and Occupy, Group D (KMA Accountants) 172 m2, Scope of work includes adding HWT, staff kitchen, two washrooms, partition walls to create offices/board room/reception area Oct 9/24 - Revision: changes to accessible washroom Existing building classification: 4 storey mixed use bldg. Floor 2 - 3.2.2.58 Group D, 823.13 m2 Commercial Office Space, Floors 3, 4 - 3.2.2.50 Group C, 1572.13 m2 Residential Apartment, 16 units, all over 3.2.2.83 Group F3, 1342 m2 parking garage. Total GFA 3743.3 m2. The Building is Sprinklered, with Fire Alarm System. Floor assemblies and load bearing walls require 1 hour FRR/ FS, STC 55 between suites & elevator, STC 50 suites & corridor. 1.5 FRR/FS between Parkade and CRU's. |
Application Status: | COMPLETED |
Permit Value: | $400,000.00 |
Builder: | TECHNIFIELD CONTRACTING LTD |
Issued Date: | September 04, 2024 |
File Close Date: | December 06, 2024 |
Expiry Date: | September 04, 2026 |
Associated Properties
Address | Zone | More |
---|---|---|
101 4474 WELLINGTON ROAD | COR3 | Property Report |
4474 WELLINGTON ROAD | Property Report |
Process Steps
Task | Status |
---|---|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
CANCELLED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PASSED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
PLUMBING FINAL
All fixtures must be in place. |
FAILED |
PLUMBING FINAL
All fixtures must be in place. |
PASSED |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
FAILED |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
PASSED |
APPROVAL-FIRE
Approval required prior to Occupancy |
APPROVED |
OCCUPANCY
Booked is this tenant space has never had an occupancy or for a change in occupancy |
FAILED |
OCCUPANCY
Booked is this tenant space has never had an occupancy or for a change in occupancy |
PASSED
2024-12-06 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.