BP130081 - 125 Bowlsby Street (Parent: 950 Old Victoria Road) (FedEx)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP130081 - 125 Bowlsby Street (Parent: 950 Old Victoria Road) (FedEx) | |
---|---|
Neighbourhood: | South End |
Street Address: | 125 Bowlsby Street (Parent: 950 Old Victoria Road) (FedEx) |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP130081 |
Date Application Submitted: | May 24, 2024 |
Application Description: |
Existing warehouse alteration (FedEx) to make building one single suite. Removing existing demising wall, installing enclosed offices on existing mezzanine, renovating existing offices, upgrading universal washroom to BCBC 2024 accessibility, adding one urinal. Adding separate warehouse staff secure entrance at SE face of building, new exit door at SE face adjacent to roll-up door, replacing existing exit man-door with roll-up vehicle access door at SW face. Occupant Load: 99 persons. Existing Building Classification (BP121198): BCBC 2006 3.2.2.70 Group F2 (BCBC 2024 3.2.2.79.), 3019 m2 building area, combustible and noncombustible construction, NFPA 13 sprinkler, fire alarm, 1 storey. Existing Alternative solution for exposed building faces, Interior Water curtain sprinklers along the NE (1 hr. FRR) and NW (2 hr. FRR) building faces. REVISION 2025-JAN-02: Add janitor room, 2 drinking fountains and 4 washrooms. REVISION 2025-MAR-24: Washroom / janitor room changes. See drawings. |
Application Status: | ACTIVE |
Permit Value: | $1,520,000.00 |
Builder: | GRASCALE DEVELOPMENTS INC |
Issued Date: | October 23, 2024 |
Expiry Date: | October 23, 2026 |
Associated Properties
Address | Zone | More |
---|---|---|
950 OLD VICTORIA ROAD | I2 | Property Report |
Process Steps
Task | Status |
---|---|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
PASSED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
SCHEDULED |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.