BP130061 - 23-3200 Island Highway North (CIBC)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP130061 - 23-3200 Island Highway North (CIBC) | |
|---|---|
| Neighbourhood: | Rutherford |
| Street Address: | 23-3200 Island Highway North (CIBC) |
| Type of Application: | Commercial / Multi-Res Alteration |
| File Number: | BP130061 |
| Date Application Submitted: | May 10, 2024 |
| Application Description: |
Unit 23(CIBC) - Alteration of Group D, 557 m2, Remove and relocate all interior partition walls, Demolition of existing male & female washroom facilities and replace with 1 new accessible and 1 new universal washroom. Relocate ATM lobby security gate. Add janitors room with mop sink and accessible staffroom with sink. Mall Classification: 2012 BCBC 3.2.2.62, Group E, non-combustible construction, sprinklered, fire alarm. 5m mall corridor, 45m TD, existing alternative solutions. Aug 21/24 - Revision: revised sprinkler layout, underslab plumbing layout received |
| Application Status: | COMPLETED |
| Permit Value: | $910,000.00 |
| Builder: | ON SITE CONSTRUCTION |
| Issued Date: | July 29, 2024 |
| File Close Date: | August 30, 2024 |
| Expiry Date: | July 29, 2026 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 3200 ISLAND HIGHWAY N | CC3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
FAILED |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
CANCELLED |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
|
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
PARTIAL |
|
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
FAILED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
CANCELLED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
|
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
FAILED |
|
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
FAILED |
|
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
PASSED |
|
PLUMBING FINAL
All fixtures must be in place. |
FAILED |
|
PLUMBING FINAL
All fixtures must be in place. |
FAILED |
|
PLUMBING FINAL
All fixtures must be in place. |
PASSED |
|
FINAL
Final approval as per requirements on plans. |
FAILED |
|
FINAL
Final approval as per requirements on plans. |
PASSED
2024-08-30 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)