BP130006 - 2512 Kenworth Road (Parent: 3411 Shenton Road)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP130006 - 2512 Kenworth Road (Parent: 3411 Shenton Road) | |
|---|---|
| Neighbourhood: | Diver Lake |
| Street Address: | 2512 Kenworth Road (Parent: 3411 Shenton Road) |
| Type of Application: | Commercial / Multi-Res Alteration |
| File Number: | BP130006 |
| Date Application Submitted: | April 04, 2024 |
| Application Description: |
Building Permit to address life safety items detailed within CIB05753 Work includes: addition of a mezzanine with racking system below. Repair of existing fire separations. Combining Units 3461 & 3451 Shenton Road, complete the installation of 5 toilets; 5 lavatories and 2 staff kitchen sink Existing building (as reflected in archived plan) 2657m2, divided by fire walls into three buildings, unsprinklered, combustible and non-combustible construction, Part 3, 1337.8m2 +1108.2m2m2 warehouse buildings + Part 9, 427.4m2 two storey office/showroom building; presently divided into tenant spaces with shared washrooms. 45 min FRR-F/S for floors and supports. Revision: Change to plumbing scope of work |
| Application Status: | ACTIVE |
| Permit Value: | $20,000.00 |
| Builder: | SAYWELL DEVELOPMENTS LTD |
| Issued Date: | July 17, 2025 |
| Expiry Date: | July 17, 2027 |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
FAILED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
FAILED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
CANCELLED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
FAILED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)