BP129924 - 19 Nicol Street (New Hope Centre)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP129924 - 19 Nicol Street (New Hope Centre) | |
---|---|
Neighbourhood: | South End |
Street Address: | 19 Nicol Street (New Hope Centre) |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP129924 |
Date Application Submitted: | March 07, 2024 |
Application Description: |
For construction of a 4 storey modular bldg addition with basement containing food services, offices and residential dormitories. Building classification 3.2.2.51 Group C with subsidiary office and food service space. Addition Building area: 212.49 m2, Total Building area 526.49 m2. Sprinklered with Fire Alarm system, Key FRR/FS are 1Hr FRR/FS at exit stairs elevator and ventilation shafts, 1Hr between dorm rooms and corridors, 2Hr at FRR/FS at kitchen exhaust shaft. Alternative solutions for Exit Exposure Protection using water curtain sprinklers at all exit paths and for Glazing in Fire Separations using water curtain sprinklers at main floor vestibule. Addition GFA: 964.75 m2. Total GFA of building: 2021.05 m2. REVISION 2025-FEB-12: See internal notes. REVISION 2025-APR-07: See internal notes. |
Application Status: | ACTIVE |
Permit Value: | $6,000,000.00 |
Building Area: |
212.49 M2 2,287.22 ft2 |
Builder: | KINETIC CONSTRUCTION LTD |
Issued Date: | November 20, 2024 |
Expiry Date: | November 20, 2026 |
Associated Properties
Address | Zone | More |
---|---|---|
19 NICOL STREET | DT4 | Property Report |
Process Steps
Task | Status |
---|---|
FOOTING/FORMS
Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
SCHEDULED |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.