BP129919 - 101-3789 Shenton Road (Diver Lake Dental)

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP129919 - 101-3789 Shenton Road (Diver Lake Dental)
Neighbourhood: Diver Lake    
Street Address: 101-3789 Shenton Road (Diver Lake Dental)
Type of Application: Leasehold Improvements
File Number: BP129919
Date Application Submitted: March 07, 2024
Application Description: Complete & Occupy, Tenant Improvement, Group D (dental office), 454.6 m2, work includes adding partition walls and plumbing fixtures including accessible washrooms, sinks, HWT, DW and CW

4 storey mixed use building commercial/residential with a storage garage. Building Classification: 3.2.2.51 Group C, 3.2.2.59 Group D, 3.2.2.88 Group F3 storage garage. Building Area: 1159 m2, combustible, sprinklered with Fire Alarm System. Key F/S are 1.5hr FRR/FS parking garage to other occupancies, 1hr FRR/FS 52 STC Corridor to suite, 1hr FRR/FS 57 STC between suites, 1hr FRR/FS 62 STC Elevator walls. 1hr FRR/FS floor assemblies and load bearing supports, storage rooms, exit stairs and elevator shaft. All doors in fire separations to be self-closing with positive latching mechanisms. Total GFA is 2320.09m2.
Application Status: COMPLETED
Permit Value: $600,000.00
Builder: RW (BOB) WALL LTD
Issued Date: May 23, 2024
File Close Date: February 21, 2025
Expiry Date: May 23, 2026

Associated Properties

Address Zone More
101   3789 SHENTON ROAD COR2 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

CANCELLED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visible for inspection.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visible for inspection.

PASSED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
PLUMBING FINAL

All fixtures must be in place.

FAILED
PLUMBING FINAL

All fixtures must be in place.

FAILED
PLUMBING FINAL

All fixtures must be in place.

PASSED
SPRINKLER FINAL

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL

Sprinkler system must be complete and operating as intended.

FAILED
OCCUPANCY

Booked is this tenant space has never had an occupancy or for a change in occupancy

FAILED
OCCUPANCY

Booked is this tenant space has never had an occupancy or for a change in occupancy

PASSED

2025-02-21

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.