BP129919 - 101-3789 Shenton Road (Diver Lake Dental)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP129919 - 101-3789 Shenton Road (Diver Lake Dental) | |
---|---|
Neighbourhood: | Diver Lake |
Street Address: | 101-3789 Shenton Road (Diver Lake Dental) |
Type of Application: | Leasehold Improvements |
File Number: | BP129919 |
Date Application Submitted: | March 07, 2024 |
Application Description: |
Complete & Occupy, Tenant Improvement, Group D (dental office), 454.6 m2, work includes adding partition walls and plumbing fixtures including accessible washrooms, sinks, HWT, DW and CW 4 storey mixed use building commercial/residential with a storage garage. Building Classification: 3.2.2.51 Group C, 3.2.2.59 Group D, 3.2.2.88 Group F3 storage garage. Building Area: 1159 m2, combustible, sprinklered with Fire Alarm System. Key F/S are 1.5hr FRR/FS parking garage to other occupancies, 1hr FRR/FS 52 STC Corridor to suite, 1hr FRR/FS 57 STC between suites, 1hr FRR/FS 62 STC Elevator walls. 1hr FRR/FS floor assemblies and load bearing supports, storage rooms, exit stairs and elevator shaft. All doors in fire separations to be self-closing with positive latching mechanisms. Total GFA is 2320.09m2. |
Application Status: | COMPLETED |
Permit Value: | $600,000.00 |
Builder: | RW (BOB) WALL LTD |
Issued Date: | May 23, 2024 |
File Close Date: | February 21, 2025 |
Expiry Date: | May 23, 2026 |
Associated Properties
Address | Zone | More |
---|---|---|
101 3789 SHENTON ROAD | COR2 | Property Report |
Process Steps
Task | Status |
---|---|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
CANCELLED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PASSED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
PLUMBING FINAL
All fixtures must be in place. |
FAILED |
PLUMBING FINAL
All fixtures must be in place. |
FAILED |
PLUMBING FINAL
All fixtures must be in place. |
PASSED |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
FAILED |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
FAILED |
OCCUPANCY
Booked is this tenant space has never had an occupancy or for a change in occupancy |
FAILED |
OCCUPANCY
Booked is this tenant space has never had an occupancy or for a change in occupancy |
PASSED
2025-02-21 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.