BP129849 - 201-4851 Cedar Ridge Place (Pharmasave)

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP129849 - 201-4851 Cedar Ridge Place (Pharmasave)
Neighbourhood: Rutherford    
Street Address: 201-4851 Cedar Ridge Place (Pharmasave)
Type of Application: Commercial / Multi-Res Alteration
File Number: BP129849
Date Application Submitted: January 30, 2024
Application Description: (Pharmasave) First occupancy of CRU shell space for a Group E occupancy. Floor area 91.75 m2. Work consists of interior partition walls, relocating 9 and adding 5 sprinkler heads, completing accessible washroom, adding1 sink and HWT. Occupant load of 10 persons total.

Existing Building classification: BCBC 2018 Group D 3.2.2.63/ Group E 3.2.2.69, 183.5 m2 building area, combustible, sprinklered including attic space with Fire Alarm System. 1 hr FRR/FS Floor/roof assembly, 1 hr FRR/FS between suites. Total GFA is 367 m2.
Application Status: COMPLETED
Permit Value: $80,000.00
Builder: LEVEL WEST CONSTRUCTION LTD
Issued Date: May 23, 2024
File Close Date: July 23, 2024
Expiry Date: May 23, 2026

Associated Properties

Address Zone More
4851 CEDAR RIDGE PLACE COR2 Property Report

Process Steps

Task Status
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

FAILED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PASSED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
SPRINKLER FINAL

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL

All fixtures must be in place.

PASSED
FINAL

Final approval as per requirements on plans.

PASSED

2024-07-23

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.