BP129724 - 1125 Seafield Crescent - BLDG 2 Parent address
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP129724 - 1125 Seafield Crescent - BLDG 2 Parent address | |
|---|---|
| Neighbourhood: | Townsite |
| Street Address: | 1125 Seafield Crescent - BLDG 2 Parent address |
| Type of Application: | Commercial / Multi / Industrial |
| File Number: | BP129724 |
| Date Application Submitted: | December 01, 2023 |
| Application Description: |
1125 Seafield Crescent (Sunfield Manor) New construction of 5 storey, 62 unit Senior Housing apartment building. Building classification: Group C 3.2.2.50, with Group F3 basement parking garage. 859.9 m2 building area, Sprinklered to NFPA 13 with Fire Alarm System, Combustible construction. Key FRR/FS are 1.5 hr FRR/FS between parking garage and other occupancies. 1 hr FRR/FS 50 STC between residential suites. 1 hr FRR/FS for public corridors, floor/roof assemblies and loadbearing supports, storage rooms, exit stairs and machine room. 1Hr FRR/FS 55 STC between residential suites and elevators. All doors in fire separations to be self-closing with positive latching mechanisms. Total GFA is 5368.09 m2. REVISION 2025-AUG-13: Foundation structural detail changes. REVISION 2025-OCT-29: Minor mechanical, plumbing and sprinkler changes. |
| Application Status: | ACTIVE |
| Permit Value: | $15,000,000.00 |
| Builder: | ISLAND WEST COAST DEVELOPMENTS |
| Issued Date: | May 01, 2025 |
| Expiry Date: | May 01, 2027 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 1125 SEAFIELD CRESCENT | CC5 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
|
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
|
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
|
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
PARTIAL |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)