BP129500 - 437 Wesley Street
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP129500 - 437 Wesley Street | |
|---|---|
| Neighbourhood: | Downtown/Old City |
| Street Address: | 437 Wesley Street |
| Type of Application: | Fire Damage |
| File Number: | BP129500 |
| Date Application Submitted: | August 08, 2023 |
| Application Description: |
Fire remediation to 3 units (#203, 303 & 403), common areas and stairs on all four floors. Work includes repairs to fire separations, insulation/vapour barrier, fire alarm devices, and replacement of finishes. One sprinkler head replaced in Unit 403. Existing Building - Supportive Housing for CMHA, Part 3 , 3.2.2.45 (BCBC2006), four storey, Group C, residential apartment building with 36 suites, with fire alarm system and fire suppression system. Accessible first storey. 1st floor = 403.8 m2, 2nd floor = 578.3 m2, 3rd floor = 578.3 m2, 4th floor = 563.8 m2. Providing 2 exits per floor. Providing 1 Hr. FRR/FS for floor assemblies, loadbearing supports. exits, public corridors (45 min permitted). |
| Application Status: | COMPLETED |
| Permit Value: | $350,000.00 |
| Issued Date: | February 01, 2024 |
| File Close Date: | July 10, 2024 |
| Expiry Date: | February 01, 2026 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 437 WESLEY STREET | DT7 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
CANCELLED |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
|
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
|
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
FAILED |
|
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
PASSED |
|
APPROVAL-FIRE
Approval required prior to Final |
APPROVED |
|
FINAL
Final Approval as per requested on plans. |
CANCELLED |
|
FINAL
Final Approval as per requested on plans. |
FAILED |
|
FINAL
Final Approval as per requested on plans. |
PASSED
2024-07-10 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.