BP129470 - 205-4750 Rutherford Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP129470 - 205-4750 Rutherford Road | |
---|---|
Neighbourhood: | Rutherford |
Street Address: | 205-4750 Rutherford Road |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP129470 |
Date Application Submitted: | August 08, 2023 |
Application Description: |
Combine existing Units 203 (Group E) and 205 (Group D) to single Unit 205 (Group D) for a new 190.91 m2 residential sales centre (for Nanaimo Retirement Living). No plumbing fixtures added, existing washroom remaining, one double bowl sink removed and services capped from old Unit 205. No modifications to existing sprinkler system, new partitions terminate below drop ceiling. Plumbing fixtures are not connected and display only. No fire separations required between adjacent suites, or between suite and public mall corridor. 0-hr FRR/FS required between suite and rear egress public corridor. Building Classification: BCBC 2012 3.2.2.62., Group E, non-combustible construction, sprinklered, fire alarm. |
Application Status: | ACTIVE |
Permit Value: | $75,000.00 |
Builder: | NANAIMO RETIREMENT LIVING LP |
Issued Date: | November 20, 2023 |
Expiry Date: | November 20, 2025 |
Associated Properties
Address | Zone | More |
---|---|---|
4750 RUTHERFORD ROAD | CC3 | Property Report |
Process Steps
Task | Status |
---|---|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
FAILED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
FAILED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
FAILED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
FAILED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
FAILED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
FINAL
Final approval as per requirements on plans. |
CANCELLED |
FINAL
Final approval as per requirements on plans. |
FAILED |
FINAL
Final approval as per requirements on plans. |
FAILED |
FINAL
Final approval as per requirements on plans. |
SCHEDULED |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.