BP129418 - 107 - 4474 Wellington Road (Rise Aesthetics)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP129418 - 107 - 4474 Wellington Road (Rise Aesthetics) | |
---|---|
Neighbourhood: | Diver Lake |
Street Address: | 107 - 4474 Wellington Road (Rise Aesthetics) |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP129418 |
Date Application Submitted: | July 06, 2023 |
Application Description: |
(Rise Aesthetics) Commercial alteration to combine two(106/107) existing shell CRUs into a single Group D (personal services) tenancy, Unit 107, 145.m2. Alteration includes new partitions and 2 universal washrooms. New plumbing; 8 hand basins, 2 WCs, 1 sink, 2 HWTs and 1 clothes washer. Sprinkler system revised for new layout. Minimum two exits required. Fire separations to be maintained. Maximum occupant load of 30. Existing building classification: 4 storey mixed use bldg. Floor 2 - 3.2.2.58 Group D, 823.13 m2 Commercial Office Space, Floors 3, 4 - 3.2.2.50 Group C, 1572.13 m2 Residential Apartment, 16 units, all over 3.2.2.83 Group F3, 1342 m2 parking garage. Total GFA 3743.3 m2. The Building is Sprinklered, with Fire Alarm System. Floor assemblies and load bearing walls require 1 hour FRR/ FS, STC 55 between suites & elevator, STC 50 suites & corridor. 1.5 FRR/FS between Parkade and CRU's. |
Application Status: | COMPLETED |
Permit Value: | $200,000.00 |
Builder: | TECHNIFIELD CONTRACTING LTD |
Issued Date: | October 18, 2023 |
File Close Date: | January 29, 2024 |
Expiry Date: | October 18, 2025 |
Associated Properties
Address | Zone | More |
---|---|---|
106 4474 WELLINGTON ROAD | COR3 | Property Report |
107 4474 WELLINGTON ROAD | COR3 | Property Report |
4474 WELLINGTON ROAD | Property Report |
Process Steps
Task | Status |
---|---|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
FAILED |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
PASSED |
PLUMBING FINAL
All fixtures must be in place. |
FAILED |
PLUMBING FINAL
All fixtures must be in place. |
PASSED |
OCCUPANCY | CANCELLED |
OCCUPANCY |
PASSED
2024-01-29 |
OCCUPANCY | CANCELLED |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.