BP128861 - 103 and 105 - 940 Old Victoria Road
Neighbourhood: South End    
Street Address: 103 and 105 - 940 Old Victoria Road
Type of Application: Commercial / Multi-Res Alteration
File Number: BP128861
Date Application Submitted: November 03, 2022
Application Description: Interior alteration to create separate existing Unit 3 CRU (New address #103, 223m2, "United Floor Covering") and combine units 4 & 5 into one CRU (New address #105, 444m2, "Anderson Windows"). Scope of work includes adding new universal washroom and repair of demising wall in Unit 3, Removal of washroom in Unit 4 (including framing and return to underslab rough in only). Minor changes to existing sprinkler system (2 new and 4 relocated heads outside of design area). Key fire separations to be maintained/provided include 45min FRR between Unit3/4, 1hr FRR/FS between Unit 2/3, and 2hr FRR for NW exterior wall per BCBC3.2.3.

Existing building classification: BCBC1992 3.2.2.51 Group F2 Warehouse, single storey, 1114m2 building area, combustible construction, sprinklered, no fire alarm system.

2023-JAN-18 REVISION: to change washroom layout.
Application Status: COMPLETED
Permit Value: $20,000.00
Builder: DEER LAKE PROPERTIES INC
Issued Date: December 07, 2022
File Close Date: February 22, 2023
Expiry Date: December 07, 2024

Associated Properties

Address Zone More
950 OLD VICTORIA ROAD I2 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PASSED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

CANCELLED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
SPRINKLER FINAL

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL

All fixtures must be in place.

FAILED
PLUMBING FINAL

All fixtures must be in place.

PASSED
APPROVAL-FIRE

Approval required prior to Occupancy

APPROVED
FINAL

Final approval as per requirements on plans.

FAILED
FINAL

Final approval as per requirements on plans.

PASSED

2023-02-22

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.