BP128776 - 355 Wakesiah Avenue (NDSS) Portable #126

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP128776 - 355 Wakesiah Avenue (NDSS) Portable #126
Neighbourhood: University District    
Street Address: 355 Wakesiah Avenue (NDSS) Portable #126
Type of Application: Locate Permit
File Number: BP128776
Date Application Submitted: September 27, 2022
Application Description: Locate portable classroom # 126, BCBC 2018, 3.2.2.28 Group A-2 occupancy area of 89m² at NDSS. Work includes fire alarm tied to main school fire alarm panel, foundation design by structural engineer, one set of exit stairs and one exit ramp, emergency lighting and exit signage. Plumbing work includes installation of hand washing sink and HWT. 1 hr FRR exterior walls as per BCBC wall type EW1A

Four portables clustered, considered one building BCBC 2018, 3.2.2.28 Group A-2 occupancy. Revised Alt Sol doc by GHL Oct. 2022
Application Status: ACTIVE
Permit Value: $40,000.00
Building Area: 89.00 M2
957.99 ft2
Issued Date: October 04, 2023
Expiry Date: October 04, 2025

Associated Properties

Address Zone More
355 WAKESIAH AVENUE CS1 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of Forms prior to any cement being poured. For Footing inspection, forms must be complete and approved plans (complete with City Stamp) must be onsite.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
FRAMING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PASSED
PAPER/FLASHING/WATERPROOFING

To take place after installation of framing, sheathing, building paper, flashing, and/or weatherproofing of openings and after window installation, but before installation of any siding product or stucco wire.

PARTIAL
PAPER/FLASHING/WATERPROOFING

To take place after installation of framing, sheathing, building paper, flashing, and/or weatherproofing of openings and after window installation, but before installation of any siding product or stucco wire.

PASSED
PLUMBING FINAL

All fixtures must be in place.

FAILED
PLUMBING FINAL

All fixtures must be in place.

FAILED
FINAL

Final approval as per requirements on plans

FAILED
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy