BP128630 - 1-4906 Wellington Road (Chester Fields)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP128630 - 1-4906 Wellington Road (Chester Fields) | |
---|---|
Neighbourhood: | Diver Lake |
Street Address: | 1-4906 Wellington Road (Chester Fields) |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP128630 |
Date Application Submitted: | July 22, 2022 |
Application Description: |
Change of use from Group A2 to Group E (Chester Fields) Total area of 582.56m2 (551.79m2 main, 30.47m2 non-accessible mezzanine). Work includes removal of vestibule and majority of mezzanine structure with remainder to be non accessible, addition of two non-loadbearing partition walls to enclose warehouse/storage area, remove 3 piece washroom on mezzanine, relocating sink to staff room and installation of 8 additional sprinkler heads. Existing Building Classification: BCBC 2006 Group E 3.2.2.62./ Group D 3.2.2.56.(units #2 and #3) Building Area 1126m2, combustible or non-combustible construction, 45min. floor assemblies & supports, 45 min. supports if of combustible construction.. 2 hr demising wall under permit BP123255. 2023-APR-14 REVISION: Existing drawings revised to reflect site conditions related to washrooms and HWT location. 2023-APR-18 REVISION: Sprinkler drawings updated to reflect as built and proposed staffroom sink removed. |
Application Status: | COMPLETED |
Permit Value: | $35,000.00 |
Builder: | SOUTH FACE CONSTRUCTION LTD |
Issued Date: | February 24, 2023 |
File Close Date: | July 10, 2023 |
Expiry Date: | February 24, 2025 |
Associated Properties
Address | Zone | More |
---|---|---|
4900 WELLINGTON ROAD | COR3 | Property Report |
Process Steps
Task | Status |
---|---|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
FAILED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
FAILED |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
PASSED |
PLUMBING FINAL
All fixtures must be in place. |
FAILED |
PLUMBING FINAL
All fixtures must be in place. |
PASSED |
FINAL
Final approval as per requirements on plans. |
FAILED |
FINAL
Final approval as per requirements on plans. |
FAILED |
FINAL
Final approval as per requirements on plans. |
PASSED
2023-07-10 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.