BP128534 - 102-540 Fifth Street (Meltwich)

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP128534 - 102-540 Fifth Street (Meltwich)
Neighbourhood: University District    
Street Address: 102-540 Fifth Street (Meltwich)
Type of Application: Commercial / Multi-Res Alteration
File Number: BP128534
Date Application Submitted: June 08, 2022
Application Description: Commercial Alteration: Unit 102 (Meltwich) Group D, Low A2 119.8m2. Interior alteration to convert existing office space to a low occupant load A2 restaurant. New permitted scope of work includes new kitchen and dining area, 1 universal washroom, 1 unisex washroom, relocation of existing sprinkler heads, 1 new head for cooler, and installation of NFPA-96 cooking hood with chemical suppression system. Maximum occupant load of 20 people (based on washrooms). Single exit with maximum travel distance of 25m. 2hr FRR/FS between suites to be maintained.

Existing Building Classification: BCBC2012 Group A2 (3.2.2.27) and Group D (3.2.2.61) occupancies, 432.9m2 building area, combustible or non combustible construction, sprinklered with fire alarm system. Existing 2hr FRR/FS between adjacent suites completed under BP111818.
Building reclassified to BCBC2018 Group A2 (3.2.2.27) and Group D (3.2.2.63).
Application Status: ACTIVE
Permit Value: $80,000.00
Issued Date: August 28, 2023
Expiry Date: August 28, 2025

Associated Properties

Address Zone More
530 FIFTH STREET CC3 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

CANCELLED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

FAILED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

FAILED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy