BP128510 - 3-5771 Turner Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP128510 - 3-5771 Turner Road | |
|---|---|
| Neighbourhood: | Rutherford |
| Street Address: | 3-5771 Turner Road |
| Type of Application: | Commercial / Multi-Res Alteration |
| File Number: | BP128510 |
| Date Application Submitted: | June 02, 2022 |
| Application Description: |
Change of Use from D Occupancy to E Occupancy (Pinnacle Pharmacy), 94 m2, 2 hour demising shaft wall built alongside of the existing demising wall under BP128237. Work includes adding sink, removing toilet and wash basin, changes to sprinkler system New building classification 2018 BCBC3.2.2.28 based on most restrictive A2 occupancy. Major occupancies are Group A2, D (BCBC3.2.2.62), and E (BCBC3.2.2.68). Total building area of 444m2, 1 storey, facing 2 streets. Sprinklered throughout by bylaw. No fire alarm system. 2022-NOV-01 REVISION: Reclassification of building to BCBC 3.2.2.28/62/68. Removal of manual stations. Clarification on fire rated assemblies. |
| Application Status: | COMPLETED |
| Permit Value: | $200,000.00 |
| Builder: | ISLAND WEST COAST DEVELOPMENT |
| Issued Date: | July 19, 2022 |
| File Close Date: | December 19, 2022 |
| Expiry Date: | July 19, 2024 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 5801 TURNER ROAD | CC3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
CANCELLED |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
|
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
FAILED |
|
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
PASSED |
|
PLUMBING FINAL
All fixtures must be in place. |
FAILED |
|
PLUMBING FINAL
All fixtures must be in place. |
PASSED |
|
FINAL
Final approval as per requirements on plans. |
PASSED
2022-12-19 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)