BP128110 - 98-3200 Island Highway North
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search Again| BP128110 - 98-3200 Island Highway North | |
|---|---|
| Neighbourhood: | Rutherford |
| Street Address: | 98-3200 Island Highway North |
| Type of Application: | Leasehold Improvements |
| File Number: | BP128110 |
| Date Application Submitted: | December 22, 2021 |
| Application Description: |
Tenant Improvement - (relocating Pita Pit) , Group A2 - 103.2 m2 . Kitchen layout and customer seating modified, washrooms enlarged/reconfigured, storage area added, no changes proposed to sprinklers, plumbing fixtures added. Mall Classification: 2012 BCBC 3.2.2.62, Group E, non-combustible construction, sprinklered, fire alarm. 5m mall corridor, 45m TD, existing alternative solutions. Mar 9/22: Revision - adding two hand sinks Mar 24/22: Revision - sprinkler head added to walk-in freezer |
| Application Status: | COMPLETED |
| Permit Value: | $100,000.00 |
| Builder: | KO CONTRACTING LTD |
| Issued Date: | January 13, 2022 |
| File Close Date: | March 29, 2022 |
| Expiry Date: | January 13, 2024 |
Associated Properties
| Address | Zone | More |
|---|---|---|
| 3200 ISLAND HIGHWAY N | CC3 | Property Report |
Process Steps
| Task | Status |
|---|---|
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PARTIAL |
|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PARTIAL |
|
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PASSED |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
|
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
|
PLUMBING FINAL
All fixtures must be in place. |
FAILED |
|
PLUMBING FINAL
All fixtures must be in place. |
PASSED |
|
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
FAILED |
|
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
PASSED |
|
FINAL
Final Approval as per requirements on plans. |
FAILED |
|
FINAL
Final Approval as per requirements on plans. |
PASSED
2022-03-29 |
| Map |
|---|
View in Google Earth (KML)
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

View in Google Earth (KML)