BP127741 - 102-5160 Dublin Way
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP127741 - 102-5160 Dublin Way | |
---|---|
Neighbourhood: | Pleasant Valley |
Street Address: | 102-5160 Dublin Way |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP127741 |
Date Application Submitted: | July 29, 2021 |
Application Description: |
Change of use from Group E (retail) to Group D (dental office) occupancy, 192.0 m2. Work includes adding accessible washroom, 6 sinks, DW, W/D, partition walls and sprinkler changes Building classified Group E 3.2.2.67. and Group D, 3.2.2.61, 2 storey, sprinklered, 3/4 hr FRR for loadbearing columns. 1hr FRR (existing) between suites, at corridor & service room separated with 1hr FRR at walls and floor, suspended slab over (parking) storage garage 2 hr FRR, 45min FRR wall assembly around elevator. Building area 859m2, 2 storeys, storage garage below considered separate building. Bldg B - Total of 8 CRU's identified as Units #101-104 (857m2) on first floor and #201-204 (859m2) on second, 798.8m2 parking garage (below- considered separate bldg), June5/24- Revision for sprinkler layout change in hallways from pendant to sidewall heads Mar 13/23 - Revision: floor layout changed, shower deleted |
Application Status: | COMPLETED |
Permit Value: | $150,000.00 |
Builder: | OMEGA CONSTRUCTION CORP |
Issued Date: | September 26, 2022 |
File Close Date: | June 13, 2024 |
Expiry Date: | September 26, 2024 |
Associated Properties
Address | Zone | More |
---|---|---|
102 5160 DUBLIN WAY | CD5 | Property Report |
Process Steps
Task | Status |
---|---|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
FAILED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
CANCELLED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
FAILED |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
PASSED |
PLUMBING FINAL
All fixtures must be in place. |
FAILED |
PLUMBING FINAL
All fixtures must be in place. |
PASSED |
FINAL
Final approval as per requirements on plans. |
FAILED |
FINAL
Final approval as per requirements on plans. |
PASSED
2024-06-13 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.