BP127636 - 5085 Uplands Drive

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP127636 - 5085 Uplands Drive
Neighbourhood: Rutherford    
Street Address: 5085 Uplands Drive
Type of Application: Commercial / Multi-Res Alteration
File Number: BP127636
Date Application Submitted: June 23, 2021
Application Description: Seismic upgrades to apartment building

Existing 59 unit apartment complex with parking garage. 7413.3 m2, 5 Storey, Group C /F3 building, classified as 3.2.2.50. and 3.2.2.80. Building is sprinklered with fire alarm system, basement and first floor are noncombustible construction and floors 2-5 are of combustible construction. Floor assemblies, mezzanines, loadbearing walls, columns and arches to have a F/S with 1 hr. F.R.R. Suites separated by a 1hr FS/FRR, elevator shaft has a 1.5hr FS/FRR and the parking garage is separated by a 1.5hr FS/FRR, floor above parking garage/ residential between first and second storey has a 1.5hr FS/FRR.
Alternative solution #1) to provide a water curtain for exit protection for the south exit stair #2.

Nov 18/21 - Revision: footing size increased, new Structural drawing received
Aug 5, 2022 - Revision: add architect for fire resistant assemblies of new structural details.
Application Status: COMPLETED
Permit Value: $125,000.00
Builder: WESTURBAN DEVELOPMENTS LTD
Issued Date: September 24, 2021
File Close Date: August 31, 2022
Expiry Date: September 24, 2023

Associated Properties

Address Zone More
5085 UPLANDS DRIVE R8 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

CANCELLED
FOOTING/FORMS

Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
FOOTING/FORMS

Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

CANCELLED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

FAILED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

CANCELLED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
FINAL

Final approval as per requirements on plans.

CANCELLED
FINAL

Final approval as per requirements on plans.

CANCELLED
FINAL

Final approval as per requirements on plans.

FAILED
FINAL

Final approval as per requirements on plans.

PASSED

2022-08-31

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy