BP127571 - 2133 Bowen Road

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP127571 - 2133 Bowen Road
Neighbourhood: Northfield    
Street Address: 2133 Bowen Road
Type of Application: Commercial / Multi-Res Alteration
File Number: BP127571
Date Application Submitted: May 13, 2021
Application Description: (Althouse Notary Office) Reconfigure office layout and decor upgrade. Work includes - adding main floor staff kitchen, revise & relocate accessible washroom layout and staff sink location,, change office partition wall locations, remove two exterior doors, add employee lounge to basement, changes to sprinkler system

Mar 3/22: Revision - adding 1 sink to basement lounge, changing interior partition layout, existing accessible washroom to remain unchanged
May 11/22: Revision - changes to sprinkler layout

Existing 2 storey Part 9 office "D" building with storage "F2" in partial basement, 376.5m2 gross floor area. Sprinklered by bylaw.
Construction requirements for left and right building face - 1 hour FRR with non-combustible cladding, single exit okay for each floor. 45min FRR at floors and stairwell. Occupant load 32 persons.
Application Status: COMPLETED
Permit Value: $150,000.00
Builder: WINDLEY CONTRACTING LTD
Issued Date: January 25, 2022
File Close Date: June 07, 2022
Expiry Date: January 25, 2024

Associated Properties

Address Zone More
2133 BOWEN ROAD COR3 Property Report

Process Steps

Task Status
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PASSED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
SPRINKLER FINAL

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL

All fixtures must be in place.

PASSED
FINAL

Final approval as per requirements on plans.

CANCELLED
FINAL

Final approval as per requirements on plans.

PASSED

2022-06-07

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy