BP127494 - 105 - 1875 Boxwood Road

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP127494 - 105 - 1875 Boxwood Road
Neighbourhood: Northfield    
Street Address: 105 - 1875 Boxwood Road
Type of Application: Commercial / Multi-Res Alteration
File Number: BP127494
Date Application Submitted: May 03, 2021
Application Description: Complete and Occupy (Medical (Mobility and Accessibility Equipment Supply), Lower Floor 787.8 m2, Upper floor 310.29 m2, Total area 1098.09 m2. Work includes adding plumbing fixtures, adding interior partition walls, sprinkler changes and converting portion of lower floor from F-2 to D occupancy.

Feb 18/22: Revision - changes to sprinkler layout, accessible routes now using CSA B651 5.1 standard (>1000 mm), boardroom partition wall moved

1,835.72 m2 Building Area, reclassified (BCBC2018) as 3.2.2.63 Group D, up to 2 stories sprinklered, 3.2.2.77. Group F2 up to 4 storeys, sprinklered. Combustible or non-combustible construction permitted. Floors, mezzanines and loadbearing assemblies require 45 min FRR/FS. North facing exterior wall requires a 2 hr FRR.
Application Status: COMPLETED
Permit Value: $685,000.00
Builder: ISLAND WEST COAST DEVELOPMENTS LTD
Issued Date: December 21, 2021
File Close Date: May 06, 2022
Expiry Date: December 21, 2023

Associated Properties

Address Zone More
106   1875 BOXWOOD ROAD I2 Property Report
105   1875 BOXWOOD ROAD I2 Property Report
104   1875 BOXWOOD ROAD I2 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PASSED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
SPRINKLER FINAL

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL

All fixtures must be in place.

FAILED
PLUMBING FINAL

All fixtures must be in place.

PASSED
OCCUPANCY FAILED
OCCUPANCY PASSED

2022-05-06

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy