BP127484 - 5019 Hinrich View
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP127484 - 5019 Hinrich View | |
---|---|
Neighbourhood: | North Slope |
Street Address: | 5019 Hinrich View |
Type of Application: | Single / Two Family Alteration |
File Number: | BP127484 |
Date Application Submitted: | May 06, 2021 |
Application Description: |
addition to upper floor, install elevator, alteration to front porch REVISION 2021-JUL-12: Retaining walls revised, fireplace relocated, window added to master bedroom. REVISION 2021-SEP-03: Add bar sink, add exterior door REVISION 2022-FEB-01: Add Structural Engineer Documents for interior/exterior topless guardrails |
Application Status: | COMPLETED |
Permit Value: | $300,000.00 |
Building Area: |
116.99 M2 1,259.27 ft2 |
Builder: | RLS CONSTRUCTION LTD |
Issued Date: | June 07, 2021 |
File Close Date: | April 20, 2022 |
Expiry Date: | June 07, 2023 |
Associated Properties
Address | Zone | More |
---|---|---|
5019 HINRICH VIEW | R6 | Property Report |
Process Steps
Task | Status |
---|---|
EXCAVATION
Excavation of soil, prior to placing forms. |
PASSED |
FOOTING/FORMS
Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any concrete being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PASSED |
ROUGH IN PLUMBING
Rough In plumbing must be complete including water piping. |
PARTIAL |
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PARTIAL |
ROUGH IN PLUMBING
Rough In plumbing must be complete including water piping. |
PASSED |
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PASSED |
FRAMING
Rough in plumbing & electrical must be complete. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection |
FAILED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection |
PASSED |
PLUMBING FINAL
All fixtures must be in place. |
SCHEDULED |
PLUMBING FINAL
All fixtures must be in place. |
SCHEDULED |
FINAL
Final approval as per requirements on plans. |
CANCELLED |
FINAL
Final approval as per requirements on plans. |
FAILED |
FINAL
Final approval as per requirements on plans. |
PASSED
2022-04-20 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.