BP127350 - 2522 Nadely Cres
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP127350 - 2522 Nadely Cres | |
---|---|
Neighbourhood: | Diver Lake |
Street Address: | 2522 Nadely Cres |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP127350 |
Date Application Submitted: | March 30, 2021 |
Application Description: |
Alteration (Jolly Giant Daycare) Change of Use of a Part 9 - SFD to Part 3 - A2/C Occupancies. (Daycare (A2) 120 m2 / Residential 237.2 m2). Alteration of washroom layouts and plumbing fixtures on upper floor, add laundry room to upper floor. Add washrooms and new laundry to new unit. New fire alarm system, structural upgrades and 1 hour (1.5 hour at garage) F.R.R. fire separation. 1 hour F.R.R. required at East and West building faces, Alternative Solution by GHL. Building: Part 3 Group A2 and Group C, combustible unsprinklered 357.2 m2 building. REVISION: Nov.22,2022-Structural changes to cantilevered framing. |
Application Status: | COMPLETED |
Permit Value: | $50,000.00 |
Builder: | SATGUR DEVELOPMENT INC |
Issued Date: | January 18, 2022 |
File Close Date: | May 03, 2023 |
Expiry Date: | January 18, 2024 |
Associated Properties
Address | Zone | More |
---|---|---|
2522 NADELY CRESCENT | R5 | Property Report |
Process Steps
Task | Status |
---|---|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
PASSED |
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PARTIAL |
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
FAILED |
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PARTIAL |
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PASSED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
FAILED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
FAILED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
APPROVAL-FIRE
Approval required prior to Occupancy |
APPROVED |
FINAL
Final approval as per requirements on plans. |
CANCELLED |
FINAL
Final approval as per requirements on plans. |
CANCELLED |
FINAL
Final approval as per requirements on plans. |
CANCELLED |
FINAL
Final approval as per requirements on plans. |
FAILED |
FINAL
Final approval as per requirements on plans. |
FAILED |
FINAL
Final approval as per requirements on plans. |
PASSED
2023-05-03 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.