BP127347 - 100-525 Third Street

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP127347 - 100-525 Third Street
Neighbourhood: University District    
Street Address: 100-525 Third Street
Type of Application: Commercial / Multi-Res Alteration
File Number: BP127347
Date Application Submitted: March 29, 2021
Application Description: (Pharmasave) Alteration to occupy a new 143.8 m2 Group E CRU by adding an office, storage room and accessible washroom. Installation of a washbasin, toilet and sink. Adding 16 sprinkler heads.

2012 BCBC Building classification: 22 Strata unit residential apartment building with 5 commercial rental units on main floor and basement level. 794 m2, 4 storey, Group C 3.2.2.50, Group E 3.2.2.65 & Parking Garage Group F2 3.2.2.82. Total area of all floors, including parking garage is 3634.4 m2. Sprinklered, Fire Alarm system, combustible and/or noncombustible construction. 1 hr. FS/F.R.R. is required between suites, suites and corridors/stairwells/elevator shaft and 1 hr. F.R.R. for floor assemblies, load-bearing walls and columns. Parking Garage is required to be separated from the remainder of the building by a 1.5 hrs. FS/F.R.R.
Application Status: COMPLETED
Permit Value: $75,000.00
Builder: LEVEL WEST CONSTRUCTION LTD
Issued Date: August 09, 2021
File Close Date: October 22, 2021
Expiry Date: August 09, 2023

Associated Properties

Address Zone More
100   525 THIRD STREET COR2 Property Report

Process Steps

Task Status
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PASSED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
SPRINKLER FINAL

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL

All fixtures must be in place.

PASSED
OCCUPANCY FAILED
OCCUPANCY PASSED

2021-10-22

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.