BP126293 - 202-5160 Dublin Way
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP126293 - 202-5160 Dublin Way | |
---|---|
Neighbourhood: | Pleasant Valley |
Street Address: | 202-5160 Dublin Way |
Type of Application: | Leasehold Improvements |
File Number: | BP126293 |
Date Application Submitted: | April 17, 2020 |
Application Description: |
Tenant Improvement for unit #202, Group D occupancy (Dentist office), 182.7 m2. Scope of work includes new interior partition walls, millwork, one "universal" washroom (rough-in under base building permit), one unisex washroom, new bar sink, HWT and new sprinkler layout. Max occupant load 20 persons. Oct 13/21: Revision - sterilization area wall length changed, door location changed for Op 4 Building classified Group E 3.2.2.67. and Group D, 3.2.2.61, 2 storey, sprinklered, 3/4 hr FRR for loadbearing columns. 1hr FRR (existing) between suites, at corridor & service room separated with 1hr FRR at walls and floor, suspended slab over (parking) storage garage 2 hr FRR, 45min FRR wall assembly around elevator. Building area 859m2, 2 storeys, storage garage below considered separate building. Bldg B - Total of 8 CRU's identified as Units #101-104 (857m2) on first floor and #201-204 (859m2) on second, 798.8m2 parking garage (below- considered separate bldg), |
Application Status: | COMPLETED |
Permit Value: | $75,000.00 |
Builder: | R W (BOB) WALL LTD |
Issued Date: | September 28, 2020 |
File Close Date: | October 14, 2021 |
Expiry Date: | September 28, 2022 |
Associated Properties
Address | Zone | More |
---|---|---|
202 5160 DUBLIN WAY | CD5 | Property Report |
Process Steps
Task | Status |
---|---|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PASSED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
FAILED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
PLUMBING FINAL
All fixtures must be in place. |
FAILED |
PLUMBING FINAL
All fixtures must be in place. |
PASSED |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
FAILED |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
PASSED |
OCCUPANCY
Booked is this tenant space has never had an occupancy or for a change in occupancy |
FAILED |
OCCUPANCY
Booked is this tenant space has never had an occupancy or for a change in occupancy |
PASSED
2021-10-14 |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.