BP126274 - 425 E Madsen Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP126274 - 425 E Madsen Road | |
---|---|
Neighbourhood: | Northfield |
Street Address: | 425 E Madsen Road |
Type of Application: | Leasehold Improvements |
File Number: | BP126274 |
Date Application Submitted: | April 14, 2020 |
Application Description: |
Installation of a 245m2 walk in freezer within the existing building. Sprinkler work includes installing 28 new sprinkler heads in the design area to protect within the cooler. Existing building Part 9, Sprinklered, Group F2, Building area 557m2 with an enclosed mezzanine 34m2 (storage and staff room) (6.1%) with small office 34m2 under mezzanine no rating required, combustible or non combustible plumbing. 1 Accessible washroom in office and 1 washroom in warehouse. 3 exits from warehouse and 1 from office. Fire alarm is not required. (BP102698) 2021-Nov.18- Change door location in coolers. |
Application Status: | COMPLETED |
Permit Value: | $120,000.00 |
Builder: | TRANSCOLD DISTRIBUTION (BC) |
Issued Date: | November 03, 2020 |
File Close Date: | December 02, 2021 |
Expiry Date: | November 03, 2022 |
Associated Properties
Address | Zone | More |
---|---|---|
425 MADSEN ROAD | I3 | Property Report |
Process Steps
Task | Status |
---|---|
FOOTING/FORMS
Inspection of Forms prior to any cement being poured for footing inspection, forms must be complete and approved plans (complete with City Stamp) must be onsite. |
PASSED |
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PASSED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
FAILED |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
PASSED |
FINAL
Final Approval as per requirements on plans. |
FAILED |
FINAL
Final Approval as per requirements on plans. |
CANCELLED |
FINAL
Final Approval as per requirements on plans. |
PASSED
2021-12-02 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.