BP126010 - 101- 6421 Applecross Road

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP126010 - 101- 6421 Applecross Road
Neighbourhood: Dover    
Street Address: 101- 6421 Applecross Road
Type of Application: Commercial / Multi-Res Alteration
File Number: BP126010
Date Application Submitted: November 28, 2019
Application Description: Alteration to divide existing CRU into 2 units - (Unit #101) - Create new CRU space for Group E occupancy(Fabric land) -1132m2 Scope of work includes installing new 1 hr FRR /FS demising wall between CRU's, interior partition walls to create new receiving room, staff kitchenette area with 1 sink and 2 accessible washrooms. Alterations to fire alarm system. No proposed sprinkler changes.

Existing Part 3 Mixed use bldg, sprinklered with fire alarm system.
Application Status: COMPLETED
Permit Value: $12,000.00
Issued Date: June 03, 2020
File Close Date: September 17, 2020
Expiry Date: June 03, 2022

Associated Properties

Address Zone More
6421 APPLECROSS ROAD CC4 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PASSED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL

Sprinkler system must be complete and operating as intended.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

FAILED
PLUMBING FINAL

All fixtures must be in place.

PASSED
APPROVAL-FIRE

Approval required prior to Occupancy

APPROVED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

FAILED
FINAL-OLD

Final approval as per requirements on plans.

PASSED

2020-09-17

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy