BP125870 - 101-5160 Dublin Way
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP125870 - 101-5160 Dublin Way | |
---|---|
Neighbourhood: | Pleasant Valley |
Street Address: | 101-5160 Dublin Way |
Type of Application: | Leasehold Improvements |
File Number: | BP125870 |
Date Application Submitted: | September 26, 2019 |
Application Description: |
(Bloom Photo Studio) Tenant Improvement for unit #101, Group D occupancy, 208.3m2. Scope of work includes new interior partition walls, mill-work, one "universal" washroom (rough-in under base building permit), one unisex washroom with staff shower, new bar sink, HWT and new sprinkler layout. Max occupant load 20 persons. Jun 9/20: Revision - changes to sprinkler layout; sidewalls changed to pendants & one head removed from in front of meeting room. Building classified Group E 3.2.2.67. and Group D, 3.2.2.61, 2 storey, sprinklered, 3/4 hr FRR for loadbearing columns. 1hr FRR (existing) between suites, at corridor & service room separated with 1hr FRR at walls and floor, suspended slab over (parking) storage garage 2 hr FRR, 45min FRR wall assembly around elevator. Building area 859m2, 2 storeys, storage garage below considered separate building. |
Application Status: | COMPLETED |
Permit Value: | $150,000.00 |
Builder: | ALAIR ENTERPRISES VANCOUVER ISLAND LTD |
Issued Date: | November 21, 2019 |
File Close Date: | March 25, 2021 |
Expiry Date: | November 22, 2021 |
Associated Properties
Address | Zone | More |
---|---|---|
101 5160 DUBLIN WAY | CD5 | Property Report |
Process Steps
Task | Status |
---|---|
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
FAILED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
FAILED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
CANCELLED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PASSED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
FAILED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
PLUMBING FINAL
All fixtures must be in place. |
PASSED |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
FAILED |
SPRINKLER FINAL
Sprinkler system must be complete and operating as intended. |
PASSED |
FINAL
Final Approval as per requirements on plans. |
FAILED |
FINAL
Final Approval as per requirements on plans. |
PASSED
2021-03-25 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.