BP125819 - 105 - 6461 Metral Drive
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP125819 - 105 - 6461 Metral Drive | |
---|---|
Neighbourhood: | Pleasant Valley |
Street Address: | 105 - 6461 Metral Drive |
Type of Application: | Commercial / Multi-Res Alteration |
File Number: | BP125819 |
Date Application Submitted: | September 09, 2019 |
Application Description: |
(Domino's Pizza Restaurant) Change of Use from Group 'E' (Retail) to Group D ('A2' Low Occupancy) - Construction of office, utility room, and two washrooms.Install a walk in cooler, pizza oven with NFPA hood. Plumbing includes 1 - two pc staff washroom, 1 - two pc accessible washroom, 1 HWT, 1- three compartment sink, 1 DW, 1 mop sink, 1 washer facility and 1 hand wash sink. Proposed sprinkler changes include installing dry head in freezer, additional intermediate heads in beside oven area and drops in T-bar ceiling. Structural Engineer for steel stud bulkheads and rough opening in roof top to accommodate duct work for hood fan. Building Area 3260 m2, single storey, A-2, and E major occupancies Reclassified BCBC 2012 3.2.2.26. Group A2 & Group E, 3.2.2.65., combustible or non-combustible construction, sprinklered with fire alarm system March 27, 2020: Revision - increase size of walk in cooler, door removed from manager's office |
Application Status: | COMPLETED |
Permit Value: | $200,000.00 |
Builder: | 7015471 Manitoba Ltd |
Issued Date: | January 21, 2020 |
File Close Date: | April 24, 2020 |
Expiry Date: | January 20, 2022 |
Associated Properties
Address | Zone | More |
---|---|---|
6461 METRAL DRIVE | CC4 | Property Report |
Process Steps
Task | Status |
---|---|
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
FAILED |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
FAILED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
CANCELLED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
FAILED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
APPROVAL-FIRE-OLD
Approval required prior to Occupancy |
COMPLETED |
FINAL-OLD
Final approval as per requirements on plans. |
PASSED
2020-04-24 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.