BP125559 - 1925 Boxwood Road (Unit 121)

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP125559 - 1925 Boxwood Road (Unit 121)
Neighbourhood: Northfield    
Street Address: 1925 Boxwood Road (Unit 121)
Type of Application: Leasehold Improvements
File Number: BP125559
Date Application Submitted: May 30, 2019
Application Description: (The Master Group - HVAC Distributor) Leasehold improvement - Unit 121, 1062 m2 of F2 warehouse space. Install interior partitions, including 145m2 of subsidiary offices and meeting room. Add 2 universal washrooms, 1 staff wash basin, 1 water fountain and 1 janitors sink. 1 Hr fire separation provided to adjacent suite (vacant shell).

Building Classification: 2012 BCBC, 3.2.2.75., Building area is 2234 m2, combustible or non-combustible construction permitted, building is sprinklered with fire alarm system, loadbearing walls, columns and arches supporting a rated assembly shall have a FRR not less than the supported element 45 min.
Original BP123885
Application Status: COMPLETED
Permit Value: $300,000.00
Builder: WINDLEY CONTRACTING LTD
Issued Date: August 27, 2019
File Close Date: February 05, 2020
Expiry Date: August 26, 2021

Associated Properties

Address Zone More
1925 BOXWOOD ROAD I2 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

FAILED
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visible for inspection.

PASSED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

CANCELLED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

FAILED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PASSED
PAPER/FLASHING/WATERPROOFING PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

FAILED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

FAILED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
APPROVAL-FIRE-OLD

Approval required prior to Occupancy

COMPLETED
OCCUPANCY-OLD PASSED

2020-02-05

FINAL-OLD

Final Approval as per requirements on plans.

FAILED
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy