BP125454 - 1608 Bowen Road

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP125454 - 1608 Bowen Road
Neighbourhood: Northfield    
Street Address: 1608 Bowen Road
Type of Application: Commercial / Multi / Industrial
File Number: BP125454
Date Application Submitted: April 23, 2019
Application Description: Four storey residential building - 48 Residential units, Group C, 3.2.2.51, 4 storey, sprinklered with standpipes in exit stairwells, fire alarm and 775.9 m2 open Parkade. Building area 1110.66 m2. Total gross floor area 3677.2 m2 (including stairwells and elevators) 1st storey = 339 m2 ; 2nd storey 1110.66 m2; 3rd storey 1114.74 m2; 4th storey 1112.8 m2. 1 Hour FRR/FS 50 STM between residential suites, 1 Hour FRR/FS for public corridor, floor assemblies and loadbearing supports, storage rooms, exit stairs, elevators and machine room; all doors in fire separations to be self-closing with positive latching mechanisms. Rated roof provided for termination vertical 1 hour FRR/FS. Vertical service spaces 45 min FS/FRR.

REVISION: June 11/20 - Change to bathroom layout in units 203, 303 & 403. This affected plumbing and sprinklers.
Application Status: COMPLETED
Permit Value: $6,116,714.00
Builder: SAYWELL CONTRACTING LTD
Issued Date: October 08, 2019
File Close Date: November 27, 2020
Expiry Date: October 07, 2021

Process Steps

Task Status
PERIMETER DRAIN

For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering.

PARTIAL
FIRELINE

Fireline for the sprinkler system must be complete and visable for inspection.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB INSULATION

Inspection required prior to placing slab concrete.

PASSED
STORM CONNECTION

Pipe and connection must be visible for inspection.

PARTIAL
SANITARY CONNECTION

Pipe and connection must be visible for inspection.

PARTIAL
WATER CONNECTION

Pipe and connection must be visible for inspection.

CANCELLED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

CANCELLED
Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.