BP125302 - 905 Hecate Street

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP125302 - 905 Hecate Street
Neighbourhood: Downtown/Old City    
Street Address: 905 Hecate Street
Type of Application: Leasehold Improvements
File Number: BP125302
Date Application Submitted: March 06, 2019
Application Description: Daycare occupancy on main and lower floor in previous Community Centre, (Nanaimo Innovation Academy), A-2 occupancy. Daycare for 32 children between the ages of 10 months and 5 years, and 8 staff members. Total occupant load for the building is 80 persons. Single occupancy building. Work includes 4 smoke detectors hardwired into fire alarm system; installation of handrails at interior and exterior stairs where missing, self-closer on door between floors, replacement of sink & grab bar in "universal" toilet room to be code compliant.
BCBC 2012: 3.2.2.28. Group A-2, One storey (138m2) on basement, combustible construction, fire alarm. First storey < 2m above grade. 3/4 hr fire separation between basement and main floor required under 3.2.1.4.

REVISION: Dec 3/19 - Changes outlined in internal notes.
REVISION: Jan 6/19 - Reconfigure bathroom and relocate dishwasher and sinks.
REVISION: Feb. 5/2020 - Change occupant Load. Max 80 persons.LB
Application Status: COMPLETED
Permit Value: $1,575.00
Issued Date: March 29, 2019
File Close Date: February 13, 2020
Expiry Date: March 29, 2021

Associated Properties

Address Zone More
905 HECATE STREET CS1 , R14 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PASSED
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
FINAL-OLD

Final Approval as per requirements on plans.

FAILED
FINAL-OLD

Final Approval as per requirements on plans.

PASSED

2020-02-13

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy