BP124834 - 102 - 6359 Hammond Bay Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP124834 - 102 - 6359 Hammond Bay Road | |
---|---|
Neighbourhood: | Rutherford |
Street Address: | 102 - 6359 Hammond Bay Road |
Type of Application: | Leasehold Improvements |
File Number: | BP124834 |
Date Application Submitted: | September 26, 2018 |
Application Description: |
Tenant improvement in unit #102, for (Denture Clinic), Group "D" service occupancy of 88.5m2. Work includes removal of interior walls and creation of new treatment rooms and reception area, addition of 4 sinks. Existing washroom to remain unchanged. Building G (6359 units 101 - 104) - 693m2, combustible construction, unsprinklered. Existing firewall between Building A ( Brick) and Building G. REVISION: Add push buttons to make a treatment room accessible. |
Application Status: | COMPLETED |
Permit Value: | $15,000.00 |
Issued Date: | February 04, 2019 |
File Close Date: | September 03, 2019 |
Expiry Date: | February 03, 2021 |
Associated Properties
Address | Zone | More |
---|---|---|
6361 HAMMOND BAY ROAD | CC4 | Property Report |
Process Steps
Task | Status |
---|---|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
CANCELLED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
FAILED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
CANCELLED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
CANCELLED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
CANCELLED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final Approval as per requirements on plans. |
CANCELLED |
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2019-09-03 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.