BP124338 - 107 - 6461 Metral Drive
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP124338 - 107 - 6461 Metral Drive | |
---|---|
Neighbourhood: | Pleasant Valley |
Street Address: | 107 - 6461 Metral Drive |
Type of Application: | Leasehold Improvements |
File Number: | BP124338 |
Date Application Submitted: | April 17, 2018 |
Application Description: |
Tenant Improvement in new CRU #107, (Simply Oak and Pine), furniture showroom, E retail occupancy, 517.2m2. Work includes new "universal" washroom, staff/office area with sink (with ceilings), storage area with full height dividing wall, four new dropped sprinkler heads. Existing 2 hr demising walls between suite. REVISION: Schedule B from B.D. McClure for Structural Building Area 3260 m2, single storey, A-2, and E major occupancies Reclassified BCBC 2012 3.2.2.26. Group A2 & Group E, 3.2.2.65., combustible or non-combustible construction, sprinklered with fire alarm system. Floor assemblies require 3/4 hr FRR. Mezzanines, loadbearing walls and columns require 3/4 hr FRR if of combustible construction. Loadbearing walls, columns & arches supporting a fire separation with a FRR shall have a FRR not less than the required for the FS. |
Application Status: | COMPLETED |
Permit Value: | $10,000.00 |
Issued Date: | August 27, 2018 |
File Close Date: | October 23, 2018 |
Expiry Date: | August 26, 2020 |
Associated Properties
Address | Zone | More |
---|---|---|
6461 METRAL DRIVE | CC4 | Property Report |
Process Steps
Task | Status |
---|---|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
FAILED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
FAILED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PASSED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
FAILED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2018-10-23 |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.