BP124309 - 101 - 4535 Uplands Drive

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP124309 - 101 - 4535 Uplands Drive
Neighbourhood: Rutherford    
Street Address: 101 - 4535 Uplands Drive
Type of Application: Leasehold Improvements
File Number: BP124309
Date Application Submitted: April 06, 2018
Application Description: Leasehold improvements for unit 101, (Speak Easy Communication & Education), Group D, 143.6m2. Work includes installing "accessible" washroom, staff room sink, sprinkler changes, creating interior offices, lunch room and reception. Location of sprinklers in this suite is restricted by GHL Alternative Solution from base building permit. Existing FS/FRR at floor exceeds required 1 hr separation between Group C and Group D occupancies. Demising walls between suites created under base building permit. Maximum occupant load 10 persons, 3.7.2.2(4) BCBC

Building Classification: Part 9, 2 storey strata, main floor Group E, mercantile and Group D, office occupancies, 560m2 with 4 CRU's, second floor Group C occupancy 465.63m2, 8 residential units. Building sprinklered, fire alarm system. 2hr horizontal FS/FRR installed under base building permit between residential and commercial units. Alternative solution for protection of openings for the east and west walls of the first storey.
Application Status: COMPLETED
Permit Value: $80,000.00
Issued Date: July 26, 2018
File Close Date: October 02, 2018
Expiry Date: July 27, 2020

Associated Properties

Address Zone More
4535 UPLANDS DRIVE COR3 Property Report
101   4535 UPLANDS DRIVE COR3 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visible for inspection.

FAILED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visible for inspection.

PASSED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PARTIAL
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
FINAL-OLD

Final Approval as per requirements on plans.

FAILED
FINAL-OLD

Final Approval as per requirements on plans.

PASSED

2018-10-02

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.