BP124242 - 3018 Ross Road
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP124242 - 3018 Ross Road | |
---|---|
Neighbourhood: | Rutherford |
Street Address: | 3018 Ross Road |
Type of Application: | Leasehold Improvements |
File Number: | BP124242 |
Date Application Submitted: | March 20, 2018 |
Application Description: |
Tenant improvement with the combining of units 3018, 3018A, and 3018B into one unit addressed as 3018 (CruisePlus) Group D Occupancy. Building will now be occupied by a single tenant. Unit area is 280.9 m2 on the lower floor and 302.2 m2 on the upper floor, for a total of 583.1 m2. New plumbing work includes two new universal toilet rooms on the first storey, a new staff area sink on the first storey, and relocation of a dishwasher on the upper storey. Work also includes removal of two exit doors and fire alarm pull stations and installation of one new exit door and fire alarm pull station all from the first storey area Part 9 Building: Building Area = 302.2 m2, Group D occupancy, two storeys, combustible construction, sprinklered with fire alarm system. 45 min FRR/FS for floor assembly, egress stairways, storey separation and loadbearing beams. Non-combustible columns on first storey are exempt from FRR under 9.10.8.11. (Part 3 as an Alternative) and 3.2.2.61. |
Application Status: | COMPLETED |
Permit Value: | $100,000.00 |
Builder: | DOGWOOD MOUNTAIN HOMES LTD |
Issued Date: | June 15, 2018 |
File Close Date: | August 23, 2018 |
Expiry Date: | June 15, 2020 |
Associated Properties
Address | Zone | More |
---|---|---|
3018 ROSS ROAD | COR3 | Property Report |
Process Steps
Task | Status |
---|---|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PARTIAL |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
PAPER/FLASHING/WATERPROOFING | PASSED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
CANCELLED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
CANCELLED |
APPROVAL-FIRE-OLD
Approval required prior to Occupancy |
COMPLETED |
FINAL-OLD
Final Approval as per requirements on plans. |
CANCELLED |
FINAL-OLD
Final Approval as per requirements on plans. |
FAILED |
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2018-08-23 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.