BP124172 - 6544 Metral Drive (Building B) (parent 6540 metral)
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP124172 - 6544 Metral Drive (Building B) (parent 6540 metral) | |
---|---|
Neighbourhood: | Pleasant Valley |
Street Address: | 6544 Metral Drive (Building B) (parent 6540 metral) |
Type of Application: | Commercial / Multi / Industrial |
File Number: | BP124172 |
Date Application Submitted: | February 28, 2018 |
Application Description: |
Construction of 5 storeys of multi-family apartments(32 units) with a 1 storey basement storage garage. total building area 3746.22 m2. 2012 BCBC Building Classified 3.2.2.50 Group C, up to 6 storey, combustible construction, sprinklered, fire alarm system over an 3.2.2.80. Group F3, Storage garage, non combustible construction. 1.5hr FS/FRR required between residential and Storage garage(2 hr provided). 1 hr FS/FRR required for floor separation and between residential units, Elevator shaft and exit stairs require 1hr FS/FRR. Construction of a 31 m2, concrete and wood frame with green roof, garbage enclosure building. REVISION: Feb. 4/2020 - Add 3 piece washrooms and walk in closet in units 105 - 405. Add mop sink in bike storage, remove storage room and mop sink, replace with postal alcove. |
Application Status: | COMPLETED |
Permit Value: | $5,211,078.00 |
Builder: | WINDLEY CONTRACTING LTD |
Issued Date: | January 08, 2019 |
File Close Date: | October 29, 2020 |
Expiry Date: | January 08, 2020 |
Associated Properties
Address | Zone | More |
---|---|---|
201 6544 METRAL DRIVE | CC4 | Property Report |
202 6544 METRAL DRIVE | CC4 | Property Report |
203 6544 METRAL DRIVE | CC4 | Property Report |
204 6544 METRAL DRIVE | CC4 | Property Report |
205 6544 METRAL DRIVE | CC4 | Property Report |
206 6544 METRAL DRIVE | CC4 | Property Report |
207 6544 METRAL DRIVE | CC4 | Property Report |
301 6544 METRAL DRIVE | CC4 | Property Report |
302 6544 METRAL DRIVE | CC4 | Property Report |
303 6544 METRAL DRIVE | CC4 | Property Report |
304 6544 METRAL DRIVE | CC4 | Property Report |
305 6544 METRAL DRIVE | CC4 | Property Report |
306 6544 METRAL DRIVE | CC4 | Property Report |
307 6544 METRAL DRIVE | CC4 | Property Report |
401 6544 METRAL DRIVE | CC4 | Property Report |
402 6544 METRAL DRIVE | CC4 | Property Report |
403 6544 METRAL DRIVE | CC4 | Property Report |
404 6544 METRAL DRIVE | CC4 | Property Report |
405 6544 METRAL DRIVE | CC4 | Property Report |
406 6544 METRAL DRIVE | CC4 | Property Report |
407 6544 METRAL DRIVE | CC4 | Property Report |
501 6544 METRAL DRIVE | CC4 | Property Report |
502 6544 METRAL DRIVE | CC4 | Property Report |
503 6544 METRAL DRIVE | CC4 | Property Report |
504 6544 METRAL DRIVE | CC4 | Property Report |
101 6544 METRAL DRIVE | CC4 | Property Report |
102 6544 METRAL DRIVE | CC4 | Property Report |
103 6544 METRAL DRIVE | CC4 | Property Report |
104 6544 METRAL DRIVE | CC4 | Property Report |
105 6544 METRAL DRIVE | CC4 | Property Report |
106 6544 METRAL DRIVE | CC4 | Property Report |
107 6544 METRAL DRIVE | CC4 | Property Report |
Process Steps
Task | Status |
---|---|
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PARTIAL |
FOOTING/FORMS
Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite. |
PASSED |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PARTIAL |
PERIMETER DRAIN
For perimeter drain, foundation walls should be damp proofed and drain tile in place with drain rock covering. |
PASSED |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
complete underslab plumbing must be visible. |
PASSED |
UNDERSLAB INSULATION
Inspection required prior to placing slab concrete. |
CANCELLED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PARTIAL |
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PARTIAL |
PAPER/FLASHING/WATERPROOFING
When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PARTIAL |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visable for inspection. |
PASSED |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PARTIAL |
FRAMING
Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval. |
PASSED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
CANCELLED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
CANCELLED |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PARTIAL |
INSULATION
Insulation and vapour barrier to be complete prior to inspection. |
PASSED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
FAILED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
FAILED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
APPROVAL-FIRE-OLD
Approval required prior to Occupancy |
COMPLETED |
OCCUPANCY-OLD | FAILED |
OCCUPANCY-OLD | FAILED |
OCCUPANCY | CANCELLED |
OCCUPANCY |
PASSED
2020-10-29 |
Map |
---|
![]() |
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.