BP124085 - 102 - 648 Terminal Avenue
Interested in this application? Login to manage subscriptions to subscribe to updates!
Search AgainBP124085 - 102 - 648 Terminal Avenue | |
---|---|
Neighbourhood: | Downtown/Old City |
Street Address: | 102 - 648 Terminal Avenue |
Type of Application: | Leasehold Improvements |
File Number: | BP124085 |
Date Application Submitted: | January 30, 2018 |
Application Description: |
(BarBurrito Restaurant) Tenant Improvement to shell space Unit #102 - 184.8 m2, Group A2, non-combustible construction, sprinklered building. Existing 2 hr F.R.R/ FS floor assemblies, suite separations 1 hr. F.R.R/ FS right side and 2 hr F.R.R/ FS left side. Install 2 accessible washrooms, maximum occupant load based on Health requirements is 50 persons. Building classification 3.2.2.23 (Group A2) 3.2.2.49 (Group D) and 3.2.2.57 (Group E), all unlimited building area, non-combustible construction, 2 hour F.R.R/FS floor assemblies, 2 Storey Sprinklered/Fire Alarm, 2,351.8 m2 (1st storey) and 2,221.8 m2 (2nd storey). Total area = 4,573.6 m2 . Alternative Solution for openings in fire separation, exit exposure and exit lobby. REVISION: Nov 2, 2018 - revise hood fan and sprinkler drawings, revise conditions to show replacement of Sprinkler Engineer for the project. |
Application Status: | COMPLETED |
Permit Value: | $75,000.00 |
Issued Date: | May 14, 2018 |
File Close Date: | November 05, 2018 |
Expiry Date: | May 13, 2020 |
Associated Properties
Address | Zone | More |
---|---|---|
650 TERMINAL AVENUE | DT6 , DT6 | Property Report |
Process Steps
Task | Status |
---|---|
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PARTIAL |
UNDERSLAB PLUMBING
Complete underslab plumbing must be visible. |
PASSED |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PARTIAL |
ROUGH IN PLUMBING
Rough in plumbing must be complete including potable water piping. |
PASSED |
ROUGH IN SPRINKLER
Rough in sprinkler must be complete and visible for inspection. |
PASSED |
FRAMING
Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval. |
PASSED |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PARTIAL |
PLUMBING FINAL-OLD
All fixtures must be in place. |
PASSED |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PARTIAL |
SPRINKLER FINAL-OLD
Sprinkler system must be complete and operating as intended. |
PASSED |
APPROVAL-FIRE-OLD
Approval required prior to Occupancy |
COMPLETED |
FINAL-OLD
Final Approval as per requirements on plans. |
PASSED
2018-11-05 |
Map |
---|
|
Disclaimer:
The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo.
Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation.
The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.
The Information Provided within this website is for Informational Purposes Only.
It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.