BP124085 - 102 - 648 Terminal Avenue

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP124085 - 102 - 648 Terminal Avenue
Neighbourhood: Downtown/Old City    
Street Address: 102 - 648 Terminal Avenue
Type of Application: Leasehold Improvements
File Number: BP124085
Date Application Submitted: January 30, 2018
Application Description: (BarBurrito Restaurant) Tenant Improvement to shell space Unit #102 - 184.8 m2, Group A2, non-combustible construction, sprinklered building. Existing 2 hr F.R.R/ FS floor assemblies, suite separations 1 hr. F.R.R/ FS right side and 2 hr F.R.R/ FS left side. Install 2 accessible washrooms, maximum occupant load based on Health requirements is 50 persons.

Building classification 3.2.2.23 (Group A2) 3.2.2.49 (Group D) and 3.2.2.57 (Group E), all unlimited building area, non-combustible construction, 2 hour F.R.R/FS floor assemblies, 2 Storey Sprinklered/Fire Alarm, 2,351.8 m2 (1st storey) and 2,221.8 m2 (2nd storey). Total area = 4,573.6 m2 . Alternative Solution for openings in fire separation, exit exposure and exit lobby.

REVISION: Nov 2, 2018 - revise hood fan and sprinkler drawings, revise conditions to show replacement of Sprinkler Engineer for the project.
Application Status: COMPLETED
Permit Value: $75,000.00
Issued Date: May 14, 2018
File Close Date: November 05, 2018
Expiry Date: May 13, 2020

Associated Properties

Address Zone More
650 TERMINAL AVENUE DT6 , DT6 Property Report

Process Steps

Task Status
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

Complete underslab plumbing must be visible.

PASSED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visible for inspection.

PASSED
FRAMING

Rough in plumbing and electrical must be complete. Survey Certificate and Truss Layouts required for approval.

PASSED
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

PASSED
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PASSED
APPROVAL-FIRE-OLD

Approval required prior to Occupancy

COMPLETED
FINAL-OLD

Final Approval as per requirements on plans.

PASSED

2018-11-05

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.