BP123978 - 2073 Boxwood (P&R Trucking)

Interested in this application? Login to manage subscriptions to subscribe to updates!

Search Again
BP123978 - 2073 Boxwood (P&R Trucking)
Neighbourhood: Northfield    
Street Address: 2073 Boxwood (P&R Trucking)
Type of Application: Commercial / Multi / Industrial
File Number: BP123978
Date Application Submitted: December 21, 2017
Application Description: (P&R Trucking) Construction of new sales/service building, Building Classification: 2012 BCBC 3.2.2.77. Group F2 and 3.2.2.61 Group D occupancies, sprinklered with fire alarm system. Lower floor area 1445.4m2, upper floor area 250.9m2 with additional 75.1m2 parts storage mezzanine. Pre Eng steel and wood frame construction. 45 min FRR F/S required for floor assemblies,loadbearing walls and columns. 2 hr FRR F/S required between service garage and remainder of building, 45 min FRR F/S required for exit stairwells, between parts storage warehouse and administration/retail areas. Alternative Solution by GHL Consultants Ltd for Fire Resistance Rating of North Building Face(water curtain).

REVISION: Jan 18/19 - New sprinkler drawings and Hydraulic Calculations.
Application Status: COMPLETED
Permit Value: $3,345,000.00
Builder: WINDLEY CONTRACTING LTD
Issued Date: July 17, 2018
File Close Date: June 11, 2019
Expiry Date: July 17, 2020

Associated Properties

Address Zone More
2073 BOXWOOD ROAD I2 Property Report

Process Steps

Task Status
FOOTING/FORMS

Inspection of forms prior to any cement being poured. For footing inspection, forms must be complete and approved plans (complete with City stamp) must be onsite.

PASSED
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PARTIAL
UNDERSLAB PLUMBING

complete underslab plumbing must be visible.

PASSED
UNDERSLAB INSULATION

Inspection required prior to placing slab concrete.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

FAILED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PARTIAL
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

FAILED
ROUGH IN PLUMBING

Rough in plumbing must be complete including potable water piping.

PASSED
PAPER/FLASHING/WATERPROOFING

When framing, sheathing, building paper, flashing, weatherproofing of openings and window installation is complete, but before installation of any siding, wire mesh or stucco.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PARTIAL
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

FAILED
ROUGH IN SPRINKLER

Rough in sprinkler must be complete and visable for inspection.

PASSED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

FAILED
FRAMING

Rough in plumbing & electrical must be complete. Survey Certificate & Truss layouts required for approval.

PARTIAL
INSULATION

Insulation and vapour barrier to be complete prior to inspection.

PARTIAL
SPRINKLER FINAL-OLD

Sprinkler system must be complete and operating as intended.

PARTIAL
PLUMBING FINAL-OLD

All fixtures must be in place.

PARTIAL
APPROVAL-FIRE-OLD

Approval required prior to Occupancy

COMPLETED
OCCUPANCY-OLD FAILED
OCCUPANCY-OLD PASSED

2019-06-11

Map
View in Google Earth (KML)


Disclaimer:

The City of Nanaimo does not endorse any information contained herein by parties not affiliated with the City of Nanaimo. Furthermore, the City of Nanaimo is providing the information contained within this website without warranty, guarantee, or further obligation. The City is not liable for any consequences or damages any individual may incur as a result of misrepresented, misquoted, or mistaken information.

The Information Provided within this website is for Informational Purposes Only. It is not meant to be an authoritative guide, and will not in any circumstances override any decisions or standards made or set by any representative or agent of the City of Nanaimo.

Help us improve our website

Don't include private or financial information in this form.

Collection and use of your personal information
Information collected on this form is done so under the general authority of the Community Charter and Freedom of Information and Protection of Privacy Act (FOIPPA), and is protected in accordance with FOIPPA.  Personal information will only be used by authorized staff to fulfill the purpose for which it was originally collected, or for a use consistent with that purpose. Questions about the collection of your personal information may be referred to the Legislative Services Department at (250) 755-4405, or via email at foi@nanaimo.ca.
Privacy Policy